Power World R290 Full DC Inverter Heat Pump is a monoblock unit, which integrates compressors, plate heat exchangers, water pumps, expansion tanks and other components of internationally renowned brands into a compact structure, which is more convenient for installers to install than split heat pumps.
Zero Carbon Emission R290 Refrigerant
Heating Capacity 8.3KW ~22KW
Working Ambient Temps Range of -25℃~43℃
Supply Heating Cooling and Domestic Hot Water Throughout the Year
Energy Level A+++ Tested by TUV
5.29 COP and 75℃ Outlet Water
Model |
PW030-DKZLRS-D/S |
PW040-DKZLRS-D/S |
PW050-DKZLRS-D/S |
PW040-DKZLRS-D |
PW050-DKZLRS-D |
PW060-DKZLRS-D |
Heating Condition - Ambient Temp.(DB/WB): 7/6℃, Water Temp.(In/Out): 30/35℃ | ||||||
Heating Capacity Range (kW) |
3.2~9.0 |
4.2~11.8 |
5.6~16.0 |
4.2~11.8 |
5.6~16.0 |
7.7~22.0 |
Heating Power Input Range(kW) |
0.68~2.18 |
0.88~2.83 |
1.16~3.80 |
0.88~2.83 |
1.16~3.80 |
1.58~5.23 |
COP Range |
4.13~4.71 |
4.17~4.75 |
4.21~4.83 |
4.17~4.75 |
4.21~4.83 |
4.21~4.86 |
DHW Condition-Ambient Temp.(DB/WB): 7/6℃,Water Temp.(In/Out):15/55℃ | ||||||
Heating Capacity Range (kW) |
2.5~7.2 |
3.3~9.4 |
4.5~12.8 |
3.3~9.4 |
4.5~12.8 |
6.2~17.6 |
Heating Power Input Range(kW) |
0.65~2.14 |
0.86~2.76 |
1.15~3.70 |
0.86~2.76 |
1.15~3.70 |
1.57~5.06 |
COP Range |
3.37~3.82 |
3.41~3.85 |
3.46~3.92 |
3.41~3.85 |
3.46~3.92 |
3.48~3.96 |
Cooling Condition - Ambient Temp.(DB/WB): 35/24℃, Water Temp.(In/Out): 12/7℃ | ||||||
Cooling Capacity Range (kW) |
2.1~5.8 |
2.9~8.2 |
4.5~12.8 |
2.9~8.2 |
4.5~12.8 |
5.4~15.3 |
Cooling Power Input Range(kW) |
0.69~2.19 |
0.95~3.07 |
1.45~4.72 |
0.95~3.07 |
1.45~4.72 |
1.73~5.60 |
EER Range |
2.65~3.04 |
2.67~3.06 |
2.71~3.10 |
2.67~3.06 |
2.71~3.10 |
2.73~3.12 |
ErP Level (35°C) |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
A+++ |
Refrigerant |
R290 |
|||||
Power supply |
230V/1Ph/50Hz/60Hz |
380V/3Ph/50-60Hz |
||||
Diameter of pipe (mm) |
DN25 |
DN25 |
DN25 |
DN25 |
DN25 |
DN25 |
Max water head (m) |
9 |
9 |
12 |
9 |
12 |
12 |
Noise dB(A) |
≤47 |
≤50 |
≤52 |
≤50 |
≤52 |
≤53 |
Net Weight (kg) |
105 |
115 |
160 |
115 |
160 |
165 |
Net Dimension (L/W/H) mm |
970×475×820 |
1080×475×970 |
1050×480×1380 |
1080×475×970 |
1050×480×1380 |
1050×480×1380 |
Operation Ambient Temp. (℃) |
-25~43℃ |
|||||
Operating water temperature (℃) |
20~65℃(DHW ) |
|||||
Operating water temperature (℃) |
20~70℃(Heating) |
|||||
Operating water temperature (℃) |
7~35℃(Cooling) |